Water resource recovery processes at Clarkson and G.E. Booth
Clarkson and G.E. Booth are in Mississauga. Both facilities are located on – and discharge treated water back into – Lake Ontario.
Clarkson
- Processes the wastewater from homes and businesses on the west side of Brampton and Mississauga.
- Designed to treat an average flow of 350,000 m3 per day (350 ML per day).
- Clarkson treatment process
G.E. Booth
- Processes the wastewater from homes and businesses in Bolton, Caledon East, the east sides of Brampton and Mississauga, as well as some areas of York Region and the City of Toronto.
- Designed to treat an average flow of 518,000 m3 per day (518 ML per day).
- G.E. Booth treatment process
Preliminary treatment – headworks
Preliminary treatment removes coarse materials that could damage or clog downstream equipment and make treatment less efficient.
Wastewater from the collections system enters the recovery facility through the headworks. The headworks consists of mechanical screens, grit removal chambers and other associated equipment.
All wastewater flows through mechanical screens. These screens capture and remove materials such as rags, plastics, metals and wipes. The screened materials are washed and compacted before disposal.
The wastewater then flows through the grit removal chambers, where a vortex-type flow pattern makes grit settle to the bottom of the tank. Every so often, grit slurry pumps remove accumulated grit, which has excess water removed before disposal.
Primary treatment – anaerobic chamber
Primary clarifiers are large tanks. They slow the flow to allow readily settleable solids to sink to the bottom of the tank.
A sludge layer forms at the bottom of the tanks where sludge collection equipment sweeps it to the collection hoppers. Skimmers remove the surface scum layer, which consists of floating materials. The sludge and scum are then pumped to the biosolids facility for processing.
"Influent" is water that flows in, while "effluent" is water that flows out.
Primary effluent refers to flow that has undergone primary treatment (whereas primary influent is the flow entering the process). This treated primary effluent then flows by gravity to the secondary treatment phase.
Secondary treatment – activated sludge and collection hoppers
The conventional activated sludge process has 3 parts: biological reactors (aeration tanks), settling tanks (secondary clarifiers) and a solids recycling stream.
Aeration tanks are large tanks where dense populations of microorganisms consume both particles and dissolved substances.
Air is bubbled up from diffusers at the bottom of the tanks to provide oxygen to the microorganisms. This air also keeps the microorganisms in suspension.
Biomass is a mass or clump of organic matter that is used as a fuel. The combined biomass of the aeration tank is called mixed liquor. The mixed liquor flows by gravity to the secondary clarifiers.
Secondary clarifiers are large tanks. They also slow the flow to allow readily settleable solids to sink to the bottom of the tank.
These tanks provide dormant conditions to settle the biomass out from the water.
The settled biomass forms a sludge layer called activated sludge. Collection equipment sweeps activated sludge into collection hoppers. A portion of the activated sludge is returned to the aeration tanks (return activated sludge) and the remainder (waste activated sludge) is removed to the biosolids facility for processing.
The treated secondary effluent is then disinfected.
Tertiary treatment – phosphorus removal
Phosphorous removal in the treatment process is enhanced using ferrous chloride. Ferrous chloride helps phosphorous in the wastewater settle to the bottom of the clarifiers.
Disinfection and outfall
Secondary effluent is disinfected to destroy disease-causing organisms prior to the release of final effluent into the environment.
Chlorination using sodium hypochlorite is used for disinfection at the G.E. Booth and Clarkson WWRRP's.
Low-level chlorine can have toxic effects on aquatic environments, so chlorination is followed by decholorination using sodium bisulphite. Sodium hypochlorite and sodium bisulphite are added before and mid-way along the outfall pipe, respectively. This allows a sufficient retention time for the corresponding chemical reactions.
Final effluent is discharged to Lake Ontario through each facility's outfall pipes, which extend over a kilometer from shore. Effluent is released via a series of ports that diffuse the water over a large area.
Solids handling process
Solids handling at the G.E. Booth WWRRP involves thickening, dewatering, incineration and ash storage in onsite lagoons. Solids handling at the Clarkson WWRRP consists of thickening, dewatering, and anaerobic digestion, with the final dewatered biosolids trucked to the G.E. Booth WWRRP for incineration.
Thickening and dewatering processes
Thickening and dewatering processes are used to reduce the liquid content of sludge and biosolids for various reasons, including increasing treatment capacity, reducing haulage volume and providing a material suitable for incineration.
Dewatering provides a higher level of liquids removal. The liquids these processes remove are returned to the liquids treatment stream. Polymers are used to increase thickening and dewatering efficiency.
Anaerobic digestion
Anaerobic digestion is a sludge stabilization process that happens in a heated, mixed, oxygen-free tank.
The anerobic digestion process receives both primary sludge and thickened waste-activated sludge. Sludge is mixed and heated in the digesters to stay between 35°C – 37°C for proper bacteria activity.
Sludge heating happens by continually recirculating the sludge through external shell and tube heat exchangers. At the Clarkson WWRRP, biogas that is produced in this process is captured and used to generate heat and electricity by cogeneration unit (cogen).
Stabilized sludge is referred to as biosolids.
Biogas handling facilities and cogeneration unit (cogen)
At the Clarkson WWRRP, digester gas that is generated in the anaerobic digesters is collected and used as fuel for the cogeneration unit and the hot water boilers.
Cogen is an effective way of providing non-conventional renewable energy to generate electricity to the internal high voltage grid and generate heat to keep the digestion tanks warm.
Gas boosters maintain the digester gas supply to the storage gas bubble for the cogen and the boilers. Excess gas that isn't used at the boiler unit is flared.
Incineration
G.E. Booth WWRRP and Clarkson WWRRP biosolids are incinerated at the G.E. Booth WWRRP.
Combustion air is fed into the windbox at the base of the incinerator. Dewatered biosolids and, if necessary, supplementary fuel (fuel oil or natural gas) is pumped into the fluidized sand bed.
Water is evaporated, and most of the solids combustion is processed within the sand bed. Final combustion happens above the bed in the freeboard section with exhaust gases exiting between 700°C – 900°C.
Exhaust air is cleaned and cooled prior to release into the atmosphere. These emissions are constantly checked by a continuous emissions monitoring system (CEMS).
Ash lagoons
The ash slurry produced from the incineration process is pumped to ash lagoons for onsite storage.
Why odours happen
When you flush a toilet or take a shower, wastewater flows through a network of underground pipes called the sanitary sewer system.
Peel Region’s wastewater system treats over 690 million litres of sewage from residents and businesses every day.
Odours are created when bacteria starts to break down waste. This happens in all sewer systems. Odour control methods can help manage or eliminate odours, and an active monitoring program helps to identify and address odour issues quickly.
Odour control and monitoring
We make every effort to control odours during the wastewater collection and treatment process by:
- Ensuring all Peel facilities meet or exceed provincial regulations.
- Continuously researching and implementing state-of-the-art treatment processes and technology.
- Maintaining an active odour monitoring program. A sensor network continuously monitors treatment plant odour, and specially trained individuals use portable equipment to regularly monitor the collection system.
- Responding quickly and thoroughly to sewer odour occurrences.
- Routinely inspecting and cleaning, as well as prioritizing higher odour-causing treatment processes.
Reporting sewage odours
To report sewage odours in any Peel community, call 905-791-7800.